Publication:

Dual-variable force characterisation method for human-robot interaction in wearable robotics

 
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0003-4881-9341
cris.virtual.orcid0000-0002-8207-0576
cris.virtual.orcid0000-0002-3987-2426
cris.virtualsource.department47530ccc-659e-457a-9b3b-557ce3dd23e7
cris.virtualsource.departmente2274d7a-1abb-471a-ad38-63da492036b7
cris.virtualsource.departmentf74c89bf-7302-4794-95a9-c816b15bbfcb
cris.virtualsource.orcid47530ccc-659e-457a-9b3b-557ce3dd23e7
cris.virtualsource.orcide2274d7a-1abb-471a-ad38-63da492036b7
cris.virtualsource.orcidf74c89bf-7302-4794-95a9-c816b15bbfcb
dc.contributor.authorBallen-Moreno, Felipe
dc.contributor.authorFerrentino, Pasquale
dc.contributor.authorAmighi, Milan
dc.contributor.authorVanderborght, Bram
dc.contributor.authorVerstraten, Tom
dc.date.accessioned2026-10-19T14:31:27Z
dc.date.available2026-10-19T14:31:27Z
dc.date.createdwos2026
dc.date.issued2026
dc.description.abstractUnderstanding the physical interaction with wearable robots is essential to ensure safety and comfort. However, this interaction is complex in two key aspects: (1) the motion involved, and (2) the non-linear behaviour of soft tissues. Multiple approaches have been undertaken to better understand this interaction and to improve the quantitative metrics of physical interfaces or cuffs. As these two topics are closely interrelated, finite modelling and soft tissue characterisation offer valuable insights into pressure distribution and shear stress induced by the cuff. Nevertheless, current characterisation methods typically rely on a single fitting variable along one degree of freedom, which limits their applicability, given that interactions with wearable robots often involve multiple degrees of freedom. To address this limitation, this work introduces a dual-variable characterisation method, involving normal and tangential forces, aimed at identifying reliable material parameters and evaluating the impact of single-variable fitting on force and torque responses. This method demonstrates the importance of incorporating two variables into the characterisation process by analysing the normalised mean square error (NMSE) across different scenarios and material models, providing a foundation for simulation at the closest possible level, with a focus on the cuff and the human limb involved in the physical interaction between the user and the wearable robot.
dc.description.wosFundingTextThis work was supported by internal fundings from Vrije Universiteit Brussel and Flanders Innovation & Entrepreneurship (HBC.2025. 0679). Computational resources used in this work were provided by the VSC (Flemish Supercomputer Center), funded by the Research Foundation-Flanders (FWO) and the Flemish Government.
dc.identifier.doi10.1016/j.jmbbm.2026.107518
dc.identifier.issn1751-6161
dc.identifier.pmidMEDLINE:42392006
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/60600
dc.language.isoeng
dc.provenance.editstepusergreet.vanhoof@imec.be
dc.publisherELSEVIER
dc.source.beginpage107518
dc.source.journalJOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS
dc.source.numberofpages9
dc.source.volume181
dc.subject.keywordsSOFT-TISSUES
dc.subject.keywordsMECHANICAL-PROPERTIES
dc.subject.keywordsINDENTATION
dc.subject.keywordsLIMB
dc.subject.keywordsMRI
dc.title

Dual-variable force characterisation method for human-robot interaction in wearable robotics

dc.typeJournal article
dspace.entity.typePublication
imec.internal.crawledAt2026-09-07
imec.internal.sourcecrawler
imec.internal.wosCreatedAt2026-09-07
Files
Publication available in collections: